Zur Navigation springen

 

Trafo shielding sheet

18,19 €
(15,28 € excl. vat)
Scale price:
  • from 3 pcs: 15,47 €*
  • from 30 pcs: 14,55 €*
  • from 100 pcs: 12,73 €*
  • from 200 pcs: 11,82 €*
* Price per unit
Scale price:
  • from 3 pcs: 15,47 €*
  • from 30 pcs: 14,55 €*
  • from 100 pcs: 12,73 €*
  • from 200 pcs: 11,82 €*
* Price per unit
including VAT., plus shipping
  • In stock!
  • Shipping time: 1 - 2 workdays
Order Now
Category
Manufacturer
Item no.
  • 20110429AT
Product weight
  • 0,03 kg
Shipping weight
  • 0,12 kg

Interesting items


  1. Trafo Shielding Plate 70mm

    Average Rating: 5/55
    starting from 8,45 €
    (7,10 € excl. vat)
    including VAT., plus shipping
  2. Trafo shielding sheet XL
    Trafo shielding sheet XL

    Average Rating: 5/55
    35,80 €
    (30,09 € excl. vat)
    including VAT., plus shipping

Description

Trafo shield for toroidal trafos: 35cm x 4cm

Our electro sheet is for use with toroidal trafos. It consists of two grain-oriented-steel layers that effects

double shielding around the toroid and 6-times shielding on the overlapping to eleminate horizontal radiation hum and noise of toroidal trafos.

The shielding sheet is placed around the toroidal transformer and the overlapping of the sheet is placed perfectly to the cable outbreak of the transformer. The shielding sheet can be fixed with a fixation tape, adhesive tape or rubber.

Commonly used to match highend stereo audio-gear that has different noise levels on left and right channel cause of trafo noise, hum. If the channel next to the toroidal trafo has a worser noise floor than the channel with greater distance to the trafo, this is an indicator for electro magnetic fields around the toroidaltransformer. In this case use the trafo shielding sheet, wrap it around your toroid-trafo to solve the electro magnetic radiation problem completely.

Specs:

  • Size: 35cm x 4cm

 

Material:

  • two layer "grain-oriented steel with 3% silizium" - "DIN46400"

 

Application:

  • trafo shielding

 

For more information (google translated - Please read the german description for original):

The effect of the electric shielding is not only cause the chemical composition, in particular its own special grain structure. In contrast to conventional steel, which consists of a chaotic arrangement of tiny crystals adhering to each other, the grains of the electro sheets are actually extremely large and also regarding orientation of their crystal axes aligned uniformly.

This equal grain orientation that matters, because the magnetisation of the material can be influenced.Cause its structure the material contracts to the de-magnetisation process very less resistance, in alternating 50 times a second, than conventional steels. Mu-metal has similar properties. This grain structure is achieved by a so-called thermo-mechanical treatment in the disturbed by a cold rolling process, the grain structure and a five to seven days a recrystallization heat treatment takes place.

How to install our sheets:
The trafo shielding sheet can be wrapped around the toroidal trafo. Fix it with a tape and take the overlapping part to the outgoing wires as descripted in the following PDF file. Fix it with a tape. For a detailled instruction take a look into the PDF.

Customer-Pics

Log in to upload a pic!



"My first dual g-pultec. The trafo shielding sheet improved the noise-floor to more than -94db. It is easy to install."

"If your stubborn like me and HAVE to fit your transformer in tight, this product can save the day. "

"My First \"Isolation \" !"

Product Tags

Other people marked this product with these tags:

Ratings from users

  • 5 Stars: 93% (14)
  • 4 Stars: 7% (1)
  • 3 Stars: 0% (0)
  • 2 Stars: 0% (0)
  • 1 Star: 0% (0)
Average product review: Average Rating: 5/55

(This product has got 15 Reviews)

Share your experience with other customers
More product reviews
  1. Average Rating: 5/55 Adam C. Wrote at 13.07.2023
    Effective Shielding
    I have bought this shielding to reduce transformer hum on a DIY Iron Pre SE preamp. My build was placed in a small DAC case, meaning the low distance between PSU toroidal trafo and output Cinemags caused a small 50 Hz hum at -114dB.
    The shielding sheet fitted exact for used trafo and greatly reduced the hum to the level under -120dB where is no longer noticeble.
  2. Average Rating: 5/55 jörg k. Wrote at 27.02.2023
    👍
    👍
  3. Average Rating: 5/55 Heinrich B. Wrote at 29.01.2023
    passt
    Schnelle Lieferung, das Abschirmblech kann leicht eigenen Anforderungen zugeschnitten und und gebogen werden. Um den Halt sicherzustellen habe ich um das Blech einen Kabelbinder angebracht. Schnittkante habe ich mit Isolierband versehen damit man sich nicht verletzen kann.
  4. Average Rating: 5/55 Geoffrey W. Wrote at 18.11.2022
    Simple and cheap fix
    After finishing my second version of Bruce Hernans http://diyaudioprojects.com/Tubes/6DJ8-Tube-Headphone-Amp/ headphone amp I was left with some slight hum when using my ZMF Verités. I bought one of the normal sized sheets, covered it in Kapton tape and bent it to fit around the Edcor XPWR083A. I could actually hear the hum just go away by putting it over.

    Very much recommended if youre using a smaller open power transformer, even a non-toroidal one. Ill be definitely picking up a second one once I get around to re-working my previous build.
  5. Average Rating: 5/55 Ralf k. Wrote at 04.11.2022
    Trafoabschirmblech
    Hallo, Trafoabschirmblech ist heute angekommen ; Ich habe das soweit möglich ( war da eher erstmal vorsichtig wg... den Kabeln : Erstmal provisorisch ..den Trafo so eng wie möglich umbunden ; Teste jetzt erstmal ....mal schauen ..es scheint klanglich schon präziser geworden zu sein ( Erstmal warm werden lassen die Class A Maschine ...- ich höre mich mal rein ; Ich denke aber man kann schon zufrieden sein ; Brummen ..ist bei mir auch mit Endsufe ...max...und Pre weit auf ....nicht zu vernehmen ...! Schauen wir mal ! Und für das Geld ? Versuch macht kluch `
  6. Average Rating: 5/55 Pedro V. Wrote at 19.03.2021
    Efectively reduces hum on integrated amp
    Bought this to reduce transformer hum on a Rega Brio-R integrated amp. This equipement is housed in a half-width case, meaning the low distance between transformer and electronics caused a small but audioble hum on speakers when sitting close to the speakers (which I am when listing to headphones).
    The trafo shielding sheet was exact size for this amp and greatly reduced the hum - to the point where is no longer noticeble.
    Installation we very easy; make sure to follow the instruction and get very tight fit around the transformer and overlap the shielding sheet near the cable exit point for maximal effectiveness.
  7. Average Rating: 4/54 Frank P. Wrote at 15.02.2020
    Funktioniert gut, aber etwas zu teuer


    Ich habe das Blech am Talema Print Ringkerntrafo eines DIY MC HeadAmps eingesetzt. Durch die hohe Verstärkung war vorher ein Netzbrummen zu hören, da die Amp Platine direkt neben dem Netzteil sitzt. Mit dem Blech ist absolute Ruhe. Das Blech läßt sich ganz einfach auch mit einer üblichen Haushaltschere zurechtschneiden. Ob so ein Blechstreifen nun tatsächlich 15€ kosten muß, so viel, wie der ganze Talema Trafo, sei dahingestellt. Deshalb ein Stern Abzug. Zähneknirschend zahlt man das, weil es nicht so einfach ist, passendes Material zu finden, ohne gleich Industriemengen abnehmen zu müssen. Aber 5-7€ wären sicher angemessener.



    Antwort von Don:



    Hallo Frank, vielen Dank für dein Feedback, Vielleicht ein paar Details zu diesem Abschirmband: Es besteht insgesamt aus zwei Blechen, die aus kernorientiertem Stahl warmgewalzt, zugeschnitten und konfektioniert werden. Da es manueller Produktionsaufwand ist und die Abnahme als Problemlöser sich in Grenzen hält, ergibt sich bei den kleineren Produktionen, die wir haben der höhere Aufwand, der sich im Preis wiederspiegelt.


  8. Average Rating: 5/55 Ari R. Wrote at 28.09.2019
    Hum stopper
    This sheet works very well.
  9. Average Rating: 5/55 Boris G. Wrote at 14.12.2017
    ringkerntrafo abschirmblech
    vorher brummte es nun nicht mehr. zweck erfüllt
  10. Average Rating: 5/55 Jan Š. Wrote at 20.10.2017
    Trafo shielding sheet used in preamps
    Hi All,
    I built 12 microphone pre-amps in one 3u rack together with quite big transformer and I found hum on the last channel. This channel is 5cm away from the transformer and I tried to shield it by thick Iron. Hum was still there. My last chance was this trafo shielding sheet before to make separate power supply box. Installation was very easy. Turn it up and Yippee! HUM is gone. I did not believe it much, but now I can only recommend it.
* All prices are final prices in EUR including the valid value added tax/VAT.